BPQFZ - 06014, ELECTRONIC CLEANER AEROSOL

  • MSDS: BPQFZ
  • Manufacturer: CRC CHEMICALS
  • Product Name: 06014, ELECTRONIC CLEANER AEROSOL
  • National Stock Number: 6850-00N033330
Product Identification

Product ID:06014, ELECTRONIC CLEANER AEROSOL
MSDS Date:07/07/1992
FSC:6850
NIIN:00N033330
MSDS Number: BPQFZ

Responsible Party
CRC CHEMICALS
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: ALLEN B. REED

Cage: CRCCE

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 75%

OSHA PEL 1000PPM;1250PPM STEL

ACGIH TLV: 1000PPM;1250PPM STEL


METHANE, CHLORODIFLUORO-;(CHLORODIFLUOROMETHANE)

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 25%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:DROWSINESS,
LIGHTHEADEDNESS, POSSIBLE CARDIAC ARRHYTHMIAS AT HIGH
CONCENTRATIONS. SKIN:DEFATTING ACTION, MAY CAUSE DERMATITIS.
EYE:MAY IRRITATE. CHRONIC:MAY CAUSE SKIN IRRITATION WITH REPE ATED
CONTACT. CHLOROFLUOROCARBON MATERIALS HAVE PRODUCED SENSITIZATION
OF THE MYOCARDIUM (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:TO EPINEPHRINE IN LAB ANIMALS AND
COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE SUSTAINING USES
IN HUMANS ACUTELY OR CHRONIC ALLY EXPOSED TO CFC'S .
Medical Cond Aggravated by Exposure:IMPAIRED CARDIOVASCULAR FUNCTION
SUCH AS CARDIAC ARRHYTHMIAS MIGHT BE SENSITIZED BY INHALATION.

First Aid

First Aid:INHAL:MOVE TO FRESH AIR. APPLY ARTIFICAL RESPIRATION IF
NECESSARY. EYE:FLUSH WITH LARGE AMOUNTS OF WATER. SKIN:WASH WITH
WATER. INGEST:INDUCE VOMITING. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOL CONTAINERS CAN EXPLODE IF
CONTENTS ARE HEATED TO MORE THAN 130F. THERMAL DECOMPOSITION
PRODUCTS MAY INCLUDE CHLORIDES, FLUORIDES AND PHOSGENE .

Accidental Release

Spill Release Procedures:DUE TO HIGH VOLATILITY MATERIAL QUICKLY
EVAPORATES. VENTILATE AREA, EVACUATE PERSONNEL UNTIL CONCENTRATION
IS BELOW TLV OR USE NIOSH/MSHA APPROVED SCBA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AEROSOL CNTNRS MAY EXPLODE IF EXPOSED
TO TEMPS >130F. VAPORS ARE VERY HEAVY & WILL COLLECT IN LOW AREAS.
O*2 WOULD BE DISPLACED & ASPHXY COULD RSLT.
Other Precautions:GOOD VENT IS MUST FOR LOW AREAS & CONFINED SPACES. NO
SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL VICINITY OF ARC
WELDING, OPEN FLAMES OR HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE THE
FORMATION OF CHLORIDES, FLUORIDES & PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SCBA IF CONCENTRATIONS ARE
ABOVE TLV.
Ventilation:MAINTAIN CONCENTRATIONS BELOW TLV.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:5.5 PSIA @ 70F.

Chemical Properties

Boiling Pt:B.P. Text:118F,48C
Melt/Freeze Pt:M.P/F.P Text:-36F,-38C
Vapor Pres:SUPDAT
Vapor Density:6.5
Spec Gravity:1.57
Evaporation Rate & Reference:0.3 (CCL*4=1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
POWDERED METALS SUCH AS ALUMINUM, MAGNESIUM, CALCIUM, ZINC.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HALOGENS, HALOGEN ACIDS, POSSIBILITY
OF PHOSGENE (THERMAL). CHLORIDES, FLUORIDES .

Disposal

Waste Disposal Methods:IF POSSIBLE PUMP INTO DRUMS FOR RECLAMATION.
DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.